Junction dose from gap error

D_j / D0 ≈ 1 + k Δg / P. Gap error times penumbra slope.

Reading speed
MatchingField matching

Governing equation

Dj/D0=1+kΔg/PD_j/D_0=1+k\,\Delta g/P

where

\Delta g
Gap error (mm)
P
Penumbra 80/20 (mm)
k
Slope factor ()
D_j/D_0
Junction dose ratio ()

Lecture brief

Historical brief

The linear-quadratic model, BED, tissue-maximum ratio and Clarkson scatter turned radiotherapy into fraction arithmetic. MU calculation on these sheets is that clinical closed form. This sheet (RTH-24 — Junction dose from gap error) is the form associated with Field matching. Working symbols: Δg\Delta g, PP, kk \rightarrow Dj/D0D_j/D_0. A 2 mm gap error on a 6 mm penumbra is a ~15–30 % junction miss. Half-beam blocks shrink this.

Purpose

Purpose: compute Dj/D0D_j/D_0 from Δg\Delta g, PP, kk in Radiotherapy via Dj/D0=1+kΔg/PD_j/D_0=1+k\,\Delta g/P D_j / D0 ≈ 1 + k Δg / P. Gap error times penumbra slope. Use it when a real radiotherapy question must be answered in SI before a code check.

Live realistic example

In symbols

Live case. Given Δg=2.000mm\Delta g = 2.000\,\mathrm{mm}, P=6.000mmP = 6.000\,\mathrm{mm}, k=0.600k = 0.600\,\mathrm{—}, the governing relation Dj/D0=1+kΔg/PD_j/D_0=1+k\,\Delta g/P yields Dj/D0=1.200D_j/D_0 = 1.200\,\mathrm{—}. Two overlapping penumbras and a hot or cold junction. Move a slider: the numbers are this situation, not a canned story.

Calculator

Inputs

Outputs

  • Junction dose ratio D_j/D_01.200
Reading speed

Watch on YouTube

Free library

Full library

Free PDF / open book

YouTube channels

RTH-24 · dose
00:0 / 00:08

Narration of this film

Two overlapping penumbras and a hot or cold junction.

A 2 mm gap error on a 6 mm penumbra is a ~15–30 % junction miss. Half-beam blocks shrink this.